devices.esphome.io
IAQ (Indoor Air Quality) Board
IAQ (Indoor Air Quality) Board
Device Type: sensorElectrical Standard: global
IAQ Board is a DIY device for measuring internal air quality running with esphome. It's quite small and is based on a custom PCB where part of the components are soldered and connected.
Here is what it can measure:
- Temperature / Humidity / Pressure
- Air particles PM1, PM2.5, PM10
- Carbon Dioxide with NDIR sensor
- Air Quality Index by EPA, based on 24h average PM2.5 particles
- Ambient light
- Total VOC (volatile organic compound)
- equivalent CO2 (not very correct compared with the NDIR sensor, but it\'s provided by the VOC sensor)
On top of that:
- At least one OLED display to show the data (can have one more on the top of the MCU board)
- three RGB wide angle LEDs with auto brightness. LED1 indicates PM2.5, LED2 - Air quality index, LED3 - CO2.
- auto night dimming of the displays and LEDs (can be disabled)
- MIN/MAX values of Temperature, PM2.5 and CO2, and 24h average PM2.5 value.
- multi function button for selection of the data to show on the display
ESPHome Configuration (basic)
uart: - rx_pin: GPIO1 baud_rate: 9600 id: pms - rx_pin: GPIO18 tx_pin: GPIO19 baud_rate: 9600 id: mh
i2c: scl: GPIO22 sda: GPIO21 frequency: 100kHz
sensor: - platform: pmsx003 type: PMSX003 uart_id: pms pm_1_0: name: "PM 1 Concentration" id: pm1 pm_2_5: name: "PM 2.5 Concentration" id: pm2_5 pm_10_0: name: "PM 10 Concentration" id: pm10
- platform: bme280 temperature: name: "Temperature" oversampling: 1x id: temp filters: - offset: -1.5
pressure: name: "Pressure" oversampling: 1x id: press humidity: name: "Humidity" oversampling: 1x id: hum address: 0x76 update_interval: 10s
- platform: mhz19 co2: name: "CO2" id: co2 temperature: name: "MH-Z19 Temperature" update_interval: 10s automatic_baseline_calibration: false uart_id: mh id: mh_sensor
- platform: tsl2561 name: "Ambient Light" update_interval: 3s id: light_sens
- platform: sgp30 eco2: name: "eCO2" accuracy_decimals: 1 id: eco2 tvoc: name: "TVOC" accuracy_decimals: 1 id: tvoc update_interval: 1s compensation: temperature_source: temp humidity_source: hum
- platform: template name: "PM2.5 24h average" id: pm2_5_avg icon: mdi:chemical-weapon unit_of_measurement: µg/m³ lambda: |- return id(pm2_5).state; update_interval: 60s filters: - sliding_window_moving_average: window_size: 1440 send_every: 1
# This is a "helper" template sensor which is doing 30 sec moving average of PM2.5# I use it for sensing in automations controlling purifiers (with Home Assistant),# in order to remove the outlier values and making the control more smooth - platform: template name: "PM2.5 median" id: pm2_5_median icon: mdi:chemical-weapon unit_of_measurement: µg/m³ lambda: |- return id(pm2_5).state; update_interval: 1s filters: - median: window_size: 30 send_every: 30 send_first_at: 15
light: - platform: neopixelbus num_leds: 3 pin: GPIO16 name: "RGB strip" id: rgb_led default_transition_length: 0s
switch: - platform: gpio name: "PMS7003_SET" pin: number: GPIO26 mode: OUTPUT restore_mode: ALWAYS_ON id: pms_set
- platform: template name: "CO2 Sensor Zero Calibration" turn_on_action: - mhz19.calibrate_zero: mh_sensor - switch.turn_off: co2_cal id: co2_cal
display: - platform: ssd1306_i2c model: "SSD1306 128x64" address: 0x3C brightness: 100% rotation: 180 id: display1 lambda: |- // enter lambda here
- platform: ssd1306_i2c model: "SSD1306 64x48" address: 0x3D brightness: 100% rotation: 270 id: display2 lambda: |- // enter lambda here
Full YAML configuration: iaq_board.yaml
Full documentation: PCB, Schematic, esphome yaml config, Video