devices.esphome.io

IAQ (Indoor Air Quality) Board

IAQ (Indoor Air Quality) Board

Device Type: sensor
Electrical Standard: global

image

IAQ Board is a DIY device for measuring internal air quality running with esphome. It's quite small and is based on a custom PCB where part of the components are soldered and connected.

Here is what it can measure:

  • Temperature / Humidity / Pressure
  • Air particles PM1, PM2.5, PM10
  • Carbon Dioxide with NDIR sensor
  • Air Quality Index by EPA, based on 24h average PM2.5 particles
  • Ambient light
  • Total VOC (volatile organic compound)
  • equivalent CO2 (not very correct compared with the NDIR sensor, but it\'s provided by the VOC sensor)

On top of that:

  • At least one OLED display to show the data (can have one more on the top of the MCU board)
  • three RGB wide angle LEDs with auto brightness. LED1 indicates PM2.5, LED2 - Air quality index, LED3 - CO2.
  • auto night dimming of the displays and LEDs (can be disabled)
  • MIN/MAX values of Temperature, PM2.5 and CO2, and 24h average PM2.5 value.
  • multi function button for selection of the data to show on the display

ESPHome Configuration (basic)

uart:
- rx_pin: GPIO1
baud_rate: 9600
id: pms
- rx_pin: GPIO18
tx_pin: GPIO19
baud_rate: 9600
id: mh
i2c:
scl: GPIO22
sda: GPIO21
frequency: 100kHz
sensor:
- platform: pmsx003
type: PMSX003
uart_id: pms
pm_1_0:
name: "PM 1 Concentration"
id: pm1
pm_2_5:
name: "PM 2.5 Concentration"
id: pm2_5
pm_10_0:
name: "PM 10 Concentration"
id: pm10
- platform: bme280
temperature:
name: "Temperature"
oversampling: 1x
id: temp
filters:
- offset: -1.5
pressure:
name: "Pressure"
oversampling: 1x
id: press
humidity:
name: "Humidity"
oversampling: 1x
id: hum
address: 0x76
update_interval: 10s
- platform: mhz19
co2:
name: "CO2"
id: co2
temperature:
name: "MH-Z19 Temperature"
update_interval: 10s
automatic_baseline_calibration: false
uart_id: mh
id: mh_sensor
- platform: tsl2561
name: "Ambient Light"
update_interval: 3s
id: light_sens
- platform: sgp30
eco2:
name: "eCO2"
accuracy_decimals: 1
id: eco2
tvoc:
name: "TVOC"
accuracy_decimals: 1
id: tvoc
update_interval: 1s
compensation:
temperature_source: temp
humidity_source: hum
- platform: template
name: "PM2.5 24h average"
id: pm2_5_avg
icon: mdi:chemical-weapon
unit_of_measurement: µg/m³
lambda: |-
return id(pm2_5).state;
update_interval: 60s
filters:
- sliding_window_moving_average:
window_size: 1440
send_every: 1
# This is a "helper" template sensor which is doing 30 sec moving average of PM2.5
# I use it for sensing in automations controlling purifiers (with Home Assistant),
# in order to remove the outlier values and making the control more smooth
- platform: template
name: "PM2.5 median"
id: pm2_5_median
icon: mdi:chemical-weapon
unit_of_measurement: µg/m³
lambda: |-
return id(pm2_5).state;
update_interval: 1s
filters:
- median:
window_size: 30
send_every: 30
send_first_at: 15
light:
- platform: neopixelbus
num_leds: 3
pin: GPIO16
name: "RGB strip"
id: rgb_led
default_transition_length: 0s
switch:
- platform: gpio
name: "PMS7003_SET"
pin:
number: GPIO26
mode: OUTPUT
restore_mode: ALWAYS_ON
id: pms_set
- platform: template
name: "CO2 Sensor Zero Calibration"
turn_on_action:
- mhz19.calibrate_zero: mh_sensor
- switch.turn_off: co2_cal
id: co2_cal
display:
- platform: ssd1306_i2c
model: "SSD1306 128x64"
address: 0x3C
brightness: 100%
rotation: 180
id: display1
lambda: |-
// enter lambda here
- platform: ssd1306_i2c
model: "SSD1306 64x48"
address: 0x3D
brightness: 100%
rotation: 270
id: display2
lambda: |-
// enter lambda here

Full YAML configuration: iaq_board.yaml

Full documentation: PCB, Schematic, esphome yaml config, Video

image