SUPERNIGHT Double Outlet Plug
SUPERNIGHT Double Outlet Plug
Device Type: plugElectrical Standard: usBoard: esp8266
Flashing
As of 2022-04-12, this device can be flashed with Tuya Convert OTA (over-the-air) out of the box with no adjustments needed. Put the device in flash mode by long-holding either button until it starts fast-flashing. This device likely cannot be opened without destruction.
GPIO Pinout
Pin | Function |
---|---|
GPIO1 | Left Outlet Button (Inverted: true) |
GPIO3 | Left Outlet Relay |
GPIO4 | HLW8012 CF1 pin |
GPIO5 | HLW8012 CF pin |
GPIO12 | Right Outlet Relay |
GPIO13 | HLW8012 SEL pin (Inverted: true) |
GPIO14 | Dual red status LED (Inverted: true |
A0 | Right Button (ADC Analog) |
General Notes
These devices appear to be individually calibrated for voltage, current, and power. As a result, you will need to measure with a multimeter and adjust the voltage divider, current resistor, and power draw accordingly. The observed range so far for voltage divider is 747-865, so the base configuration has been adjusted to be the average of range at 806 for likely best default settings. The observed range so far for the current resistor is 0.00113-0.0013, so the base configuration is set to 0.001215. You can adjust the voltage divider, current resistor and power line curve in the substitutions section if needed. You need to adjust the voltage divider and current resistor before making power adjustments.
There is an oddity with restoring the value of the right relay because of the analog switch and its values during boot up. Because of this, the default configuration won't allow the right button to be pressed until the device is fully booted up, otherwise it will randomly change the state of the right outlet at startup. The measured time of unavailablity of the right button is about 8 seconds as a result.
The nightlight feature cannot be controlled by the ESP IO, and cannot be disabled without physical changes.
Basic Configuration
# Basic Configesphome: name: double-outlet-plug platform: esp8266 board: esp8285 esp8266_restore_from_flash: true # Because the right button is analog, its value will change to unpredictable # values during the boot process. We must wait until the boot process has # loaded all sensors. on_boot: # 600 did not work, 250 works, and values inbetween also did not work. As a # result, there is a delay between when you insert the plug into the wall # and when you can use the button for the right outlet. This is the safest # option to restore the correct value at a minor inconvenience. # This appears to make the right button unavailable for the first 8 seconds. priority: 250.0 then: globals.set: id: allow_analog_button_input value: 'true'
# These values may need to be calibrated per device to correct displayed values# for amperage, voltage, and power.substitutions: # You must get current and voltage correct before calibrating power. # Observered current resistor values from 2 units: 0.00113-0.0013 current_resistor: '0.001215' # Observed voltage divider values from 2 units: 747-865 voltage_divider: '806' # The value 'Power' shows by default is incorrect, to add a linear correction # place a known entity and set the calibration data here. calibration_pre_cal_power_value: '129.1' calibration_expected_correct_value: '60.0'
logger:api:ota:web_server:time: - platform: sntp id: the_timewifi: ssid: !secret wifi_ssid password: !secret wifi_password ap: ssid: "Supernight Fallback Hotspot" password: !secret wifi_ap_passwordcaptive_portal:
# We don't want to allow analog input until bootup is complete.globals: - id: allow_analog_button_input type: bool restore_value: no initial_value: 'false'
# GPIO14 is the red LED for both the left and right buttons together.# They cannot be controlled individually.# The blue LEDs turn on automatically with each respective relay and cannot be# controlled manually.# The nightlight is attached to a physical light sensor and is not controlled# by any IO and cannot be disabled by configuration.status_led: pin: number: GPIO14 inverted: true
binary_sensor: - platform: gpio pin: number: GPIO1 mode: INPUT_PULLUP inverted: true id: left_outlet_button on_press: - switch.toggle: relay_left_outlet
switch: - platform: gpio name: "Left Outlet" pin: GPIO3 id: relay_left_outlet restore_mode: RESTORE_DEFAULT_OFF - platform: gpio name: "Right Outlet" pin: GPIO12 id: relay_right_outlet # I'm unsure why, but the preference randomly saved incorrectly, and should # not be considered safe/reliable for the right outlet. restore_mode: RESTORE_DEFAULT_OFF
sensor: - platform: wifi_signal name: "wifi_signal" - platform: hlw8012 sel_pin: number: GPIO13 inverted: true cf_pin: GPIO5 cf1_pin: GPIO4 current_resistor: ${current_resistor} voltage_divider: ${voltage_divider} current: name: "Current" voltage: name: "Voltage" power: name: "Power" unit_of_measurement: W id: wattage filters: - calibrate_linear: # Map 0.0 (from sensor) to 0.0 (true value) - 0.0 -> 0.0 # No load - ${calibration_pre_cal_power_value} -> ${calibration_expected_correct_value} energy: name: "Energy" unit_of_measurement: "kWh" accuracy_decimals: 3 filters: - multiply: 0.001 update_interval: 60s # The right button is analog, and has a value of 4 when pressed and 1024 # when not pressed. - platform: adc pin: A0 id: analog_button raw: true # This needs to be short enough for the buttons to appear responsive. # 100ms was chosen because it seems sufficient for momentary detection. update_interval: 100ms # There is no real unit of measurement for this, and default V is confusing. unit_of_measurement: "" # Only trigger when the change is larger than the delta of 50. filters: - delta: 50 on_value: lambda: !lambda |- if (id(allow_analog_button_input) && id(analog_button).state < 50) { // Right outlet button is being pushed. id(relay_right_outlet).toggle(); }