substitutions: node_name: qs-wifi-ds02 node_id: IP_name friendly_node_name: "Dual Channel Dimmer"
esphome: name: ${node_name} comment: ${friendly_node_name} platform: ESP8266 board: esp01_1m
wifi: ssid: !secret wifi_ssid password: !secret wifi_pw power_save_mode: none
# Enable fallback hotspot (captive portal) in case wifi connection fails ap: ssid: ${node_name} FB password: "fallback"
captive_portal:
# Enable Home Assistant APIapi: encryption: key: !secret api_encryption
# Enable Over The Air updatesota:
# Disable logginglogger: baud_rate: 0 logs: sensor: ERROR duty_cycle: ERROR binary_sensor: ERROR light: ERROR
# Enable Web server.web_server: port: 80
# Sync time with Home Assistant.time: - platform: homeassistant id: ${node_id}_homeassistant_time
# Binary Sensors.binary_sensor: - platform: status name: ${friendly_node_name} Connection Status id: ${node_id}_connection_status #Binary sensor (on/off) which reads duty_cyle sensor readings. CH1 - platform: template id: switch1 internal: true name: "${node_id} Switch Binary Sensor 1" # read duty_cycle, convert to on/off lambda: |- if (id(sensor_push_switch_1).state < 95.0) { return true; } else { return false; } # Short Click - toggle light only on_click: max_length: 300ms then: light.toggle: light_main_1 # Generic On_Press - log press, toggle DIM Direction and reset press interval counter on_press: then: - logger.log: "Switch 1 Press" - lambda: |- if (id(g_direction_1) == 0) { id(g_direction_1) = 1; } else { id(g_direction_1) = 0; } id(g_counter_1) = 0; #Binary sensor (on/off) which reads duty_cyle sensor readings. CH2 - platform: template id: switch2 internal: true name: "${node_id} Switch Binary Sensor 2" # read duty_cycle, convert to on/off lambda: |- if (id(sensor_push_switch_2).state < 95.0) { return true; } else { return false; } # Short Click - toggle light only on_click: max_length: 300ms then: light.toggle: light_main_2 # Generic On_Press - log press, toggle DIM Direction and reset press interval counter on_press: then: - logger.log: "Switch 2 Press" - lambda: |- if (id(g_direction_2) == 0) { id(g_direction_2) = 1; } else { id(g_direction_2) = 0; } id(g_counter_2) = 0;# Sensors.sensor: - platform: uptime name: Uptime Sensor id: uptime_sensor update_interval: 600s on_raw_value: then: - text_sensor.template.publish: id: uptime_human state: !lambda |- int seconds = round(id(uptime_sensor).raw_state); int days = seconds / (24 * 3600); seconds = seconds % (24 * 3600); int hours = seconds / 3600; seconds = seconds % 3600; int minutes = seconds / 60; seconds = seconds % 60; return ( (days ? to_string(days) + "d " : "") + (hours ? to_string(hours) + "h " : "") + (minutes ? to_string(minutes) + "m " : "") + (to_string(seconds) + "s") ).c_str(); - platform: wifi_signal name: ${friendly_node_name} WiFi Signal id: ${node_id}_wifi_signal update_interval: 60s # Primary template sensor to track Brightness of light object for "on_value" sending to MCU dimmer # CH1 - platform: template name: "${node_id} Brightness Sensor CH1" id: sensor_g_bright_1 internal: true update_interval: 20ms # Ensure on_value only triggered when brightness (0-255) changes filters: delta: 0.8 # Read brightness (0 - 1) from light , convert to (0-255) for MCU lambda: |- if (id(light_main_1).remote_values.is_on()) { return (int(id(light_main_1).remote_values.get_brightness() * 255)); } else { return 0; } # On Change send to MCU via UART on_value: then: - uart.write: !lambda |- return {0xFF, 0x55, 0x01, (char) id(sensor_g_bright_1).state, 0x00, 0x00, 0x00, 0x0A}; - logger.log: level: INFO format: "CH1 Sensor Value Change sent to UART %3.1f" args: ["id(sensor_g_bright_1).state"] # Sensor to detect button push (via duty_cycle of 50hz mains signal) - platform: template name: "${node_id} Brightness Sensor CH2" id: sensor_g_bright_2 internal: true update_interval: 20ms # Ensure on_value only triggered when brightness (0-255) changes filters: delta: 0.8 # Read brightness (0 - 1) from light , convert to (0-255) for MCU lambda: |- if (id(light_main_2).remote_values.is_on()) { return (int(id(light_main_2).remote_values.get_brightness() * 255)); } else { return 0; } # On Change send to MCU via UART on_value: then: - uart.write: !lambda |- return {0xFF, 0x55, 0x02, 0x00, (char) id(sensor_g_bright_2).state, 0x00, 0x00, 0x0A}; - logger.log: level: INFO format: "CH2 Sensor Value Change sent to UART %3.1f" args: ["id(sensor_g_bright_2).state"] # Sensor to detect button push (via duty_cycle of 50hz mains signal) - platform: duty_cycle pin: GPIO13 internal: true id: sensor_push_switch_1 name: "${node_id} Sensor Push Switch 1" update_interval: 20ms - platform: duty_cycle pin: GPIO5 internal: true id: sensor_push_switch_2 name: "${node_id} Sensor Push Switch 2" update_interval: 20ms
# Text Sensors.text_sensor: - platform: template name: Uptime Human Readable id: uptime_human icon: mdi:clock-start
- platform: version name: ${friendly_node_name} ESPHome Version id: ${node_id}_esphome_version
- platform: wifi_info ip_address: name: ${friendly_node_name} IP Address id: ${node_id}_ip_address icon: mdi:ip-network
# Switches.switch: - platform: restart name: ${friendly_node_name} Restart id: ${node_id}_restart icon: "mdi:restart" - platform: shutdown name: ${friendly_node_name} Shutdown id: ${node_id}_shutdown - platform: safe_mode name: ${friendly_node_name} Restart (Safe Mode)" id: ${node_id}_safe_mode
globals: # Dim direction for Switch 1: 0=Up (brighten) 1=down (dim) - id: g_direction_1 type: int restore_value: no initial_value: "1" # Counter for time pressed for switch 1 - id: g_counter_1 type: int restore_value: no initial_value: "0" # initial brightness # Dim direction for Switch 2: 0=Up (brighten) 1=down (dim) - id: g_direction_2 type: int restore_value: no initial_value: "1" # Counter for time pressed for switch 2 - id: g_counter_2 type: int restore_value: no initial_value: "0" # initial brightness
# Uart definition to talk to MCU dimmeruart: tx_pin: GPIO1 rx_pin: GPIO3 stop_bits: 1 baud_rate: 9600
# Dummy light output to allow creation of light objectoutput: - platform: esp8266_pwm pin: GPIO14 frequency: 800 Hz id: dummy_pwm1 - platform: esp8266_pwm pin: GPIO16 frequency: 800 Hz id: dummy_pwm2
# Primary Light object exposed to HAlight: - platform: monochromatic default_transition_length: 20ms restore_mode: RESTORE_DEFAULT_OFF name: "${node_id} Light 1" output: dummy_pwm1 id: light_main_1 - platform: monochromatic default_transition_length: 20ms restore_mode: RESTORE_DEFAULT_OFF name: "${node_id} Light 2" output: dummy_pwm2 id: light_main_2
# Polling object for long press handling of switch for dim/brighten cycleinterval: - interval: 20ms then: - if: condition: binary_sensor.is_on: switch1 then: # Ramp rate for dim is product of interval (20ms) * number of intervals # Every 20ms Dimmer is increased/decreased by 2/255 # Lower limit = 10% # Upper limit = 100% # 100% - 10% = 90% = 230/255. Therefore 230/2 * 20ms = 2.3 seconds for full range # At full/min brightness - further 16x20ms = 0.32 Seconds "dwell" by resetting counter to 0 # Initial pause for 16x20ms = 0.32s to allow "on_click" to be discounted 1st # g_direction_1 = 0 (Increasing brightness) # g_direction_1 = 1 (decreasing brightness) # g_counter_1 = Interval pulse counter
lambda: |- float curr_bright = id(light_main_1).remote_values.get_brightness(); id(g_counter_1) += 1; // If max bright, change direction if (curr_bright >= 0.999 && id(g_direction_1) == 0) { id(g_direction_1) = 1; id(g_counter_1) = 0; } // If below min_bright, change direction if (curr_bright < 0.1 && id(g_direction_1) == 1) { id(g_direction_1) = 0; id(g_counter_1) = 0; } if (id(g_direction_1) == 0 && id(g_counter_1) > 15) { // Increase Bright auto call = id(light_main_1).turn_on(); call.set_brightness(curr_bright + (2.0/255.0)); call.perform(); } else if(id(g_direction_1) == 1 && id(g_counter_1) > 15) { // Decrease Bright auto call = id(light_main_1).turn_on(); call.set_brightness(curr_bright - (2.0/255.0)); call.perform(); } - if: condition: binary_sensor.is_on: switch2 then: # Ramp rate for dim is product of interval (20ms) * number of intervals # Every 20ms Dimmer is increased/decreased by 2/255 # Lower limit = 10% # Upper limit = 100% # 100% - 10% = 90% = 230/255. Therefore 230/2 * 20ms = 2.3 seconds for full range # At full/min brightness - further 16x20ms = 0.32 Seconds "dwell" by resetting counter to 0 # Initial pause for 16x20ms = 0.32s to allow "on_click" to be discounted 1st # g_direction_1 = 0 (Increasing brightness) # g_direction_1 = 1 (decreasing brightness) # g_counter_1 = Interval pulse counter
lambda: |- float curr_bright = id(light_main_2).remote_values.get_brightness(); id(g_counter_2) += 1; // If max bright, change direction if (curr_bright >= 0.999 && id(g_direction_2) == 0) { id(g_direction_2) = 1; id(g_counter_2) = 0; } // If below min_bright, change direction if (curr_bright < 0.1 && id(g_direction_2) == 1) { id(g_direction_2) = 0; id(g_counter_2) = 0; } if (id(g_direction_2) == 0 && id(g_counter_2) > 15) { // Increase Bright auto call = id(light_main_2).turn_on(); call.set_brightness(curr_bright + (2.0/255.0)); call.perform(); } else if(id(g_direction_2) == 1 && id(g_counter_2) > 15) { // Decrease Bright auto call = id(light_main_2).turn_on(); call.set_brightness(curr_bright - (2.0/255.0)); call.perform(); }