TH3D EZPlug+
Device Type:
Electrical Standard:
Board:
GPIO Pinout
| Pin | Function |
|---|---|
| GPIO3 | Button Input |
| GPIO4 | BL0937 Ennergy Meter CF |
| GPIO5 | HLW8012 Power Sensor CF1 |
| GPIO12 | HLW8012 Power Sensor SEL (Inverted) |
| GPIO13 | Status LED (Inverted) |
| GPIO14 | Relay |
Configuration Notes
- This includes basic overcurrent protection in the form of an automation
- Voltage divider is configured as I found mine, but you will need to verify your own voltage/current/power calibration
Basic Configuration
esphome: name: TH3D_EZPlug_Plus restore_from_flash: true early_pin_init: true
esp8266: board: esp01_1m
wifi: ssid: !secret wifi_ssid password: !secret wifi_password
logger:api:ota:
time: - platform: homeassistant
switch: - platform: restart name: Restarttext_sensor: - platform: version name: Version - platform: wifi_info ip_address: name: IP Address ssid: name: SSID bssid: name: BSSID mac_address: name: MAC Address scan_results: name: Scan Resultsswitch: - platform: gpio pin: GPIO14 id: relay restore_mode: RESTORE_DEFAULT_OFF name: Relay on_turn_on: - light.turn_on: led on_turn_off: - light.turn_off: led
sensor: - platform: uptime name: Uptime device_class: "duration" unit_of_measurement: s accuracy_decimals: 0 - platform: wifi_signal name: Wifi Signal Strength update_interval: 5min - platform: hlw8012 sel_pin: number: GPIO12 inverted: true cf_pin: GPIO4 cf1_pin: GPIO5 model: BL0937 voltage_divider: 512 current: name: Current unit_of_measurement: A accuracy_decimals: 3 # Overcurrent protection. Device is rated for 15A on_value_range: - above: 15 then: - switch.turn_off: relay - homeassistant.service: service: persistent_notification.create data: title: Message from TH3D_EZPlug_Plus data_template: message: Switch turned off because power exceeded 15A voltage: name: Voltage unit_of_measurement: V accuracy_decimals: 1 power: name: Power id: power unit_of_measurement: "W" accuracy_decimals: 0 icon: mdi:flash-outline change_mode_every: 1 update_interval: 2s - platform: total_daily_energy name: Daily Energy power_id: power filters: # 1 W = .001 kW - multiply: 0.001 unit_of_measurement: kWh
binary_sensor: - platform: status name: Status - platform: gpio pin: number: GPIO3 mode: INPUT_PULLUP inverted: True name: Button on_press: - switch.toggle: relay
light: - platform: status_led id: led pin: number: GPIO13 inverted: True