Westek In-Wall Smart Switch
Notes
GPIO4 is used as a status LED — the same GPIO used for status LEDs across similar MJ S01/ST01 devices.
If the LED state appears inverted, toggle inverted: true on the status LED output.
This switch has two paddle buttons (upper and lower), both of which toggle the relay.
GPIO Pinout
| Pin | Function |
|---|---|
| GPIO4 | Status LED (active HIGH — adjust if inverted) |
| GPIO12 | Relay output (active HIGH) |
| GPIO13 | Upper paddle button (active LOW, pull-up) |
| GPIO14 | Lower paddle button (active LOW, pull-up) |
Basic Configuration
substitutions:
device_name: "westek-in-wall"
esphome:
name: ${device_name}
friendly_name: "Westek In-Wall Switch"
comment: "Westek In-Wall Smart Switch"
name_add_mac_suffix: true
project:
name: Westek.InWall
version: 1.0.0
esp8266:
board: esp01_1m
restore_from_flash: true
preferences:
flash_write_interval: 1min
logger:
api:
time:
- platform: homeassistant
id: homeassistant_time
ota:
- platform: esphome
wifi:
ap: {}
captive_portal:
# GPIO Pin Mapping:
# GPIO4 - Status LED (active HIGH; toggle inverted if LED is on when it should be off)
# GPIO12 - Relay output, active HIGH
# GPIO13 - Upper paddle button, active LOW
# GPIO14 - Lower paddle button, active LOW
switch:
- platform: gpio
name: "Switch"
id: relay
pin:
number: GPIO12
inverted: false
restore_mode: RESTORE_DEFAULT_OFF
on_turn_on:
- output.turn_on: status_led
on_turn_off:
- output.turn_off: status_led
binary_sensor:
- platform: gpio
name: "Upper Paddle"
internal: true
pin:
number: GPIO13
inverted: true
mode: INPUT_PULLUP
on_press:
- switch.toggle: relay
- platform: gpio
name: "Lower Paddle"
internal: true
pin:
number: GPIO14
inverted: true
mode: INPUT_PULLUP
on_press:
- switch.toggle: relay
output:
- platform: gpio
id: status_led
pin:
number: GPIO4
inverted: false # Toggle to true if LED is on when it should be off
button:
- platform: restart
id: restart_button
name: "Restart"
- platform: safe_mode
id: restart_button_safe_mode
name: "Restart (Safe Mode)"
- platform: factory_reset
id: factory_reset_button
name: "Factory Reset"
disabled_by_default: true
entity_category: config
icon: mdi:restart-alert
sensor:
- platform: wifi_signal
name: "WiFi Signal"
update_interval: 60s
- platform: uptime
name: "Uptime"
text_sensor:
- platform: version
name: "ESPHome Version"
- platform: wifi_info
ip_address:
name: "IP Address"
mac_address:
name: "MAC Address"
ssid: