Device Type:sensor
Electrical Standard:global
Board:esp32

KinCony-N30 AC energy meter

Product

Resources

ESPHome Configuration

Here is an example YAML configuration for the KinCony N10 AC energy meter board.

esphome:
name: n30
friendly_name: n30

esp32:
board: esp32-s3-devkitc-1
framework:
type: arduino

# Enable logging
logger:
# baud_rate: 0

# Enable Home Assistant API
api:

ota:
platform: esphome

ethernet:
type: W5500
clk_pin: GPIO42
mosi_pin: GPIO43
miso_pin: GPIO44
cs_pin: GPIO41
interrupt_pin: GPIO2
reset_pin: GPIO1

uart:
rx_pin: 9
tx_pin: 10
baud_rate: 115200
stop_bits: 1
data_bits: 8
parity: NONE

text_sensor:
- platform: ethernet_info
ip_address:
name: ESP IP Address
id: eth_ip
address_0:
name: ESP IP Address 0
address_1:
name: ESP IP Address 1
address_2:
name: ESP IP Address 2
address_3:
name: ESP IP Address 3
address_4:
name: ESP IP Address 4
dns_address:
name: ESP DNS Address
mac_address:
name: ESP MAC Address

font:
- file: "gfonts://Roboto"
id: roboto
size: 15

i2c:
sda: 18
scl: 17

display:
- platform: ssd1306_i2c
model: "SSD1306 128x64"
address: 0x3C
lambda: |-
it.printf(0, 15, id(roboto), "IP: %s", id(eth_ip).state.c_str());

modbus:

modbus_controller:
- address: 1
update_interval: 5s

sensor:
- platform: modbus_controller
address: 100
register_type: holding
name: bl0910_1_current_1
id: n30_1_current_1
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001

- platform: modbus_controller
address: 102
register_type: holding
name: bl0910_1_current_2
id: n30_1_current_2
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001

- platform: modbus_controller
address: 104
register_type: holding
name: bl0910_1_current_3
id: n30_1_current_3
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001

- platform: modbus_controller
address: 106
register_type: holding
name: bl0910_1_current_4
id: n30_1_current_4
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001

- platform: modbus_controller
address: 108
register_type: holding
name: bl0910_1_current_5
id: n30_1_current_5
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001

- platform: modbus_controller
address: 110
register_type: holding
name: bl0910_1_current_6
id: n30_1_current_6
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001

- platform: modbus_controller
address: 112
register_type: holding
name: bl0910_1_current_7
id: n30_1_current_7
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001

- platform: modbus_controller
address: 114
register_type: holding
name: bl0910_1_current_8
id: n30_1_current_8
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001

- platform: modbus_controller
address: 116
register_type: holding
name: bl0910_1_current_9
id: n30_1_current_9
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001

- platform: modbus_controller
address: 118
register_type: holding
name: bl0910_1_current_10
id: n30_1_current_10
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001

- platform: modbus_controller
address: 120
register_type: holding
name: bl0910_1_power_1
id: n30_1_watt_1
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1

- platform: modbus_controller
address: 122
register_type: holding
name: bl0910_1_power_2
id: n30_1_watt_2
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1

- platform: modbus_controller
address: 124
register_type: holding
name: bl0910_1_power_3
id: n30_1_watt_3
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1

- platform: modbus_controller
address: 126
register_type: holding
name: bl0910_1_power_4
id: n30_1_watt_4
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1

- platform: modbus_controller
address: 128
register_type: holding
name: bl0910_1_power_5
id: n30_1_watt_5
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1

- platform: modbus_controller
address: 130
register_type: holding
name: bl0910_1_power_6
id: n30_1_watt_6
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1

- platform: modbus_controller
address: 132
register_type: holding
name: bl0910_1_power_7
id: n30_1_watt_7
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1

- platform: modbus_controller
address: 134
register_type: holding
name: bl0910_1_power_8
id: n30_1_watt_8
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1

- platform: modbus_controller
address: 136
register_type: holding
name: bl0910_1_power_9
id: n30_1_watt_9
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1

- platform: modbus_controller
address: 138
register_type: holding
name: bl0910_1_power_10
id: n30_1_watt_10
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 140
register_type: holding
name: bl0910_1_energy_1
id: n30_1_energy_1
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 142
register_type: holding
name: bl0910_1_energy_2
id: n30_1_energy_2
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 144
register_type: holding
name: bl0910_1_energy_3
id: n30_1_energy_3
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 146
register_type: holding
name: bl0910_1_energy_4
id: n30_1_energy_4
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 148
register_type: holding
name: bl0910_1_energy_5
id: n30_1_energy_5
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 150
register_type: holding
name: bl0910_1_energy_6
id: n30_1_energy_6
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 152
register_type: holding
name: bl0910_1_energy_7
id: n30_1_energy_7
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 154
register_type: holding
name: bl0910_1_energy_8
id: n30_1_energy_8
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 156
register_type: holding
name: bl0910_1_energy_9
id: n30_1_energy_9
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 158
register_type: holding
name: bl0910_1_energy_10
id: n30_1_energy_10
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
state_class: total_increasing
device_class: energy
address: 160
register_type: holding
name: bl0910_1_energy_sum
id: n30_1_energy_sum
unit_of_measurement: kWh
accuracy_decimals: 1
value_type: U_DWORD_R

- platform: modbus_controller
address: 162
register_type: holding
name: bl0910_1_voltage
id: n30_1_voltage
unit_of_measurement: V
device_class: voltage
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.01

- platform: modbus_controller
address: 163
register_type: holding
name: bl0910_1_frequency
id: n30_1_period
unit_of_measurement: Hz
device_class: frequency
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.01

- platform: modbus_controller
address: 164
register_type: holding
name: bl0910_1_tps1
id: n30_1_tps_1
unit_of_measurement: °C
device_class: temperature
accuracy_decimals: 1
value_type: FP32_R

- platform: modbus_controller
address: 200
register_type: holding
name: bl0910_2_current_1
id: n30_2_current_1
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 202
register_type: holding
name: bl0910_2_current_2
id: n30_2_current_2
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 204
register_type: holding
name: bl0910_2_current_3
id: n30_2_current_3
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 206
register_type: holding
name: bl0910_2_current_4
id: n30_2_current_4
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 208
register_type: holding
name: bl0910_2_current_5
id: n30_2_current_5
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 210
register_type: holding
name: bl0910_2_current_6
id: n30_2_current_6
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 212
register_type: holding
name: bl0910_2_current_7
id: n30_2_current_7
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 214
register_type: holding
name: bl0910_2_current_8
id: n30_2_current_8
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 216
register_type: holding
name: bl0910_2_current_9
id: n30_2_current_9
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 218
register_type: holding
name: bl0910_2_current_10
id: n30_2_current_10
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 220
register_type: holding
name: bl0910_2_power_1
id: n30_2_watt_1
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 222
register_type: holding
name: bl0910_2_power_2
id: n30_2_watt_2
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 224
register_type: holding
name: bl0910_2_power_3
id: n30_2_watt_3
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 226
register_type: holding
name: bl0910_2_power_4
id: n30_2_watt_4
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 228
register_type: holding
name: bl0910_2_power_5
id: n30_2_watt_5
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 230
register_type: holding
name: bl0910_2_power_6
id: n30_2_watt_6
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 232
register_type: holding
name: bl0910_2_power_7
id: n30_2_watt_7
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 234
register_type: holding
name: bl0910_2_power_8
id: n30_2_watt_8
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 236
register_type: holding
name: bl0910_2_power_9
id: n30_2_watt_9
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 238
register_type: holding
name: bl0910_2_power_10
id: n30_2_watt_10
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 240
register_type: holding
name: bl0910_2_energy_1
id: n30_2_energy_1
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 242
register_type: holding
name: bl0910_2_energy_2
id: n30_2_energy_2
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 244
register_type: holding
name: bl0910_2_energy_3
id: n30_2_energy_3
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 246
register_type: holding
name: bl0910_2_energy_4
id: n30_2_energy_4
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 248
register_type: holding
name: bl0910_2_energy_5
id: n30_2_energy_5
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 250
register_type: holding
name: bl0910_2_energy_6
id: n30_2_energy_6
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 252
register_type: holding
name: bl0910_2_energy_7
id: n30_2_energy_7
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 254
register_type: holding
name: bl0910_2_energy_8
id: n30_2_energy_8
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 256
register_type: holding
name: bl0910_2_energy_9
id: n30_2_energy_9
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 258
register_type: holding
name: bl0910_2_energy_10
id: n30_2_energy_10
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 260
register_type: holding
name: bl0910_2_energy_sum
id: n30_2_energy_sum
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 262
register_type: holding
name: bl0910_2_voltage
id: n30_2_voltage
unit_of_measurement: V
device_class: voltage
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.01
- platform: modbus_controller
address: 263
register_type: holding
name: bl0910_2_frequency
id: n30_2_period
unit_of_measurement: Hz
device_class: frequency
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.01
- platform: modbus_controller
address: 264
register_type: holding
name: bl0910_2_tps1
id: n30_2_tps_1
unit_of_measurement: "°C"
device_class: temperature
accuracy_decimals: 1
value_type: FP32_R
- platform: modbus_controller
address: 300
register_type: holding
name: bl0910_3_current_1
id: n30_3_current_1
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 302
register_type: holding
name: bl0910_3_current_2
id: n30_3_current_2
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 304
register_type: holding
name: bl0910_3_current_3
id: n30_3_current_3
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 306
register_type: holding
name: bl0910_3_current_4
id: n30_3_current_4
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 308
register_type: holding
name: bl0910_3_current_5
id: n30_3_current_5
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 310
register_type: holding
name: bl0910_3_current_6
id: n30_3_current_6
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 312
register_type: holding
name: bl0910_3_current_7
id: n30_3_current_7
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 314
register_type: holding
name: bl0910_3_current_8
id: n30_3_current_8
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 316
register_type: holding
name: bl0910_3_current_9
id: n30_3_current_9
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 318
register_type: holding
name: bl0910_3_current_10
id: n30_3_current_10
unit_of_measurement: A
device_class: current
accuracy_decimals: 3
value_type: U_DWORD_R
filters:
- multiply: 0.001
- platform: modbus_controller
address: 320
register_type: holding
name: bl0910_3_power_1
id: n30_3_watt_1
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 322
register_type: holding
name: bl0910_3_power_2
id: n30_3_watt_2
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 324
register_type: holding
name: bl0910_3_power_3
id: n30_3_watt_3
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 326
register_type: holding
name: bl0910_3_power_4
id: n30_3_watt_4
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 328
register_type: holding
name: bl0910_3_power_5
id: n30_3_watt_5
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 330
register_type: holding
name: bl0910_3_power_6
id: n30_3_watt_6
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 332
register_type: holding
name: bl0910_3_power_7
id: n30_3_watt_7
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 334
register_type: holding
name: bl0910_3_power_8
id: n30_3_watt_8
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 336
register_type: holding
name: bl0910_3_power_9
id: n30_3_watt_9
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 338
register_type: holding
name: bl0910_3_power_10
id: n30_3_watt_10
unit_of_measurement: W
device_class: power
accuracy_decimals: 1
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller
address: 340
register_type: holding
name: bl0910_3_energy_1
id: n30_3_energy_1
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 342
register_type: holding
name: bl0910_3_energy_2
id: n30_3_energy_2
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 344
register_type: holding
name: bl0910_3_energy_3
id: n30_3_energy_3
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 346
register_type: holding
name: bl0910_3_energy_4
id: n30_3_energy_4
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 348
register_type: holding
name: bl0910_3_energy_5
id: n30_3_energy_5
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 350
register_type: holding
name: bl0910_3_energy_6
id: n30_3_energy_6
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 352
register_type: holding
name: bl0910_3_energy_7
id: n30_3_energy_7
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 354
register_type: holding
name: bl0910_3_energy_8
id: n30_3_energy_8
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 356
register_type: holding
name: bl0910_3_energy_9
id: n30_3_energy_9
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 358
register_type: holding
name: bl0910_3_energy_10
id: n30_3_energy_10
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 360
register_type: holding
name: bl0910_3_energy_sum
id: n30_3_energy_sum
unit_of_measurement: kWh
device_class: energy
accuracy_decimals: 1
value_type: U_DWORD_R
state_class: total_increasing
- platform: modbus_controller
address: 362
register_type: holding
name: bl0910_3_voltage
id: n30_3_voltage
unit_of_measurement: V
device_class: voltage
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.01
- platform: modbus_controller
address: 363
register_type: holding
name: bl0910_3_frequency
id: n30_3_period
unit_of_measurement: Hz
device_class: frequency
accuracy_decimals: 1
value_type: U_WORD
filters:
- multiply: 0.01
- platform: modbus_controller
address: 364
register_type: holding
name: bl0910_3_tps1
id: n30_3_tps_1
unit_of_measurement: "°C"
device_class: temperature
accuracy_decimals: 1
value_type: FP32_R